{"product_id":"fluke-726-precision-multifunction-process-calibrator","title":"Fluke 726 Precision Multifunction Process Calibrator","description":"\u003cp\u003e\u003cstrong\u003eModel: \u003c\/strong\u003eFluke 726 Precision Multifunction Process Calibrator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e726\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003e1A4130\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/726.pdf?v=1788893723\" title=\"Fluke 726\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eGet More Calibration Power\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 726 Precision\u003cspan\u003e \u003c\/span\u003eMultifunction Process Calibrator\u003cspan\u003e \u003c\/span\u003eis designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIncludes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne set of AC72 alligator clips\u003c\/li\u003e\n\u003cli\u003eOne set of stackable test leads\u003c\/li\u003e\n\u003cli\u003eOne set of TL75 testleads\u003c\/li\u003e\n\u003cli\u003eUser manuals\u003c\/li\u003e\n\u003cli\u003eNIST- traceable calibration report and data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Fluke 726 Precision Multifunction Process Calibrator is precise and powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMore precise measurement and calibration source performance, accuracies of 0.01%.\u003c\/li\u003e\n\u003cli\u003eTwo separate channels; measure, source and view process signals simultaneously\u003c\/li\u003e\n\u003cli\u003eMeasure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters\u003c\/li\u003e\n\u003cli\u003eSource\/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters\u003c\/li\u003e\n\u003cli\u003eMeasure or source pressure* using any of 29 Fluke 700Pxx Pressure Modules\u003c\/li\u003e\n\u003cli\u003eSource mA with simultaneous pressure measurement to conduct valve and I\/P tests\u003c\/li\u003e\n\u003cli\u003eIntegrated pressure switch test allows you to capture the set, reset and deadband of a switch\u003c\/li\u003e\n\u003cli\u003eMemory storage for up to 8 calibration results, return stored calibration data from the field for later analysis\u003c\/li\u003e\n\u003cli\u003eTransmitter error % calculation, interpret calibration results without a calculator\u003c\/li\u003e\n\u003cli\u003ePerform fast linearity tests with auto step and auto ramp features\u003c\/li\u003e\n\u003cli\u003ePower transmitters during test using 24 V loop supply and simultaneous mA measurement\u003c\/li\u003e\n\u003cli\u003eStore frequently-used test setups for later use\u003c\/li\u003e\n\u003cli\u003eFrequency totalizer and frequency pulse train source mode for enhanced flowmeter testing\u003c\/li\u003e\n\u003cli\u003eHART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation\u003c\/li\u003e\n\u003cli\u003eCustom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.\u003c\/li\u003e\n\u003cli\u003eNew voltage input protection design for improved reliability\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e650 g (23 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"25%\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e30.000 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (upper display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV (lower display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e24.000 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%+ 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.0 to 4000.0 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e2.0 to 1000.0 CPM\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.00 to 15.00 kHz\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e1 V peak-to-peak-minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSource Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e100.00 mV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.000 V\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10.00 mV to 75.00 mV\u003c\/td\u003e\n\u003ctd\u003e0.025% + 1 count (via TC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e24.000 mA (Source)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24.000 mA (Simulate)\u003c\/td\u003e\n\u003ctd\u003e0.01% + 2 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResistance\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cb\u003eRange, accuracy (percent of reading + floor) and excitation current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e2.0 to 1000.0 CPM\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 1000.0 Hz\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0 to 10.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 to 15.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003e5 V p-p squarewave, -0.1 V offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eRTDs and Thermocouples\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"23\"\u003eMeasure and source accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eCu10\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNI-120\u003c\/td\u003e\n\u003ctd\u003e0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (385)\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (392)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-100 (391-JIS)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-200 (385)\u003c\/td\u003e\n\u003ctd\u003e0.95°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-500 (385)\u003c\/td\u003e\n\u003ctd\u003e0.55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT-1000 (385)\u003c\/td\u003e\n\u003ctd\u003e0.35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01°C (0.01°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu10.01 C\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e1.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU\u003c\/td\u003e\n\u003ctd\u003e0.45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003e0.6°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXK\u003c\/td\u003e\n\u003ctd\u003e0.4°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBP\u003c\/td\u003e\n\u003ctd\u003e1.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC Resolution\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41638119178298,"sku":"1A4130","price":5899.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/726-01b-600x402_540px.png?v=1788893832","url":"https:\/\/diymetering.com\/products\/fluke-726-precision-multifunction-process-calibrator","provider":"DIYmetering","version":"1.0","type":"link"}