{"title":"Clamp-On Meters","description":"\u003cp\u003eClamp-on meters\u003c\/p\u003e","products":[{"product_id":"fluke-376-fc-true-rms-ac-dc-clamp-meter-with-iflex","title":"Fluke 376 FC True-rms AC\/DC Clamp Meter with iFlex","description":"\u003cp\u003e\u003cstrong\u003eModel: \u003c\/strong\u003eFluke 376 FC True-rms AC\/DC Clamp Meter with iFlex\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e376 FC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003e1C7459\u003c\/p\u003e\n\u003cp\u003eThe Fluke 376 FC is part of the Fluke Connect family of wireless test tools.  Now you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLog and trend measurements to pinpoint intermittent faults\u003c\/li\u003e\n\u003cli\u003eTransmit results wirelessly via Fluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eMeasurements app\u003c\/li\u003e\n\u003cli\u003eCreate and send reports right from the field\u003c\/li\u003e\n\u003cli\u003eStay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"small-font\"\u003e\u003cstrong\u003eThe Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIncludes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGeneral Specifications\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5% ±5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 @ 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFlexible Current Probe\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A (≤ 600 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 at 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1.42 at 2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 20 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e20 Hz to 100 Hz, ≥20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e100 Hz to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePosition Sensitivity\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003ctd\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003ctd\u003e±1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003ctd\u003e±2.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% ±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V (≤600.0 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTrigger level \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 Hz to 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Hz to 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e100 Hz to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω (≤600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 Ω (≤6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Ω (≤60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 μF (≤ 100 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eMechanical Specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10°C)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤90% RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e≤75% RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e≤45% RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e395 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41632570736698,"sku":null,"price":699.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/F-376fc_16a_600x402_c8df0931-1a68-4327-b409-bea971dc81b4.png?v=1788553780"},{"product_id":"fluke-773","title":"Fluke 773","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e Fluke 773 Milliamp Process Clamp Meter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FLK-773\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e FLK-773\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure 4 to 20 mA signals without breaking the loop\u003c\/li\u003e\n\u003cli\u003eSource\/simulate 4 to 20 mA signals and provide loop power\u003c\/li\u003e\n\u003cli\u003eSource\/measure DC voltage to verify power supplies or I\/O signals\u003c\/li\u003e\n\u003cli\u003eBest in class accuracy of 0.2%\u003c\/li\u003e\n\u003cli\u003eDelivers 0.01 mA resolution and sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSave time and money by measuring output signals without shutting down the system\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4–20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.\u003c\/p\u003e\n\u003cp\u003eThe 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.\u003c\/p\u003e\n\u003cp\u003eThe 773 also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.\u003c\/p\u003e\n\u003ch3\u003eWork smarter with the 778 mA Clamp Meter\u003c\/h3\u003e\n\u003cp\u003eAn integrated measurement spotlight allows you to illuminate hard to see wires in dark enclosures while a dual backlit display can show mA measurement and percent of 4 to 20 mA span simultaneously. Use the Hold function to capture measurements on-screen for verification and recording purposes. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.\u003c\/p\u003e\n\u003ch3\u003eAdvanced loop troubleshooting\u003c\/h3\u003e\n\u003cp\u003eWith the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing transmitter. You can also apply a mA input signal to a device and measure its 4-20 mA output on devices such as valves or mA isolators. Offers mA or voltage output linear ramp or 25% step output.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41637383045178,"sku":"FLK-773","price":1956.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/773.webp?v=1788876579"},{"product_id":"fluke-323-true-rms-clamp-meter","title":"Fluke 323 True RMS Clamp Meter","description":"\u003cp\u003e\u003cstrong\u003eModel: \u003c\/strong\u003eFluke 323 True RMS Clamp Meter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e323\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003e1C2090\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFluke rugged. Fluke reliable. Fluke precise.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIncludes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSlim, ergonomic design\u003c\/li\u003e\n\u003cli\u003eCAT IV 300V\/CAT III 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eHold button\u003c\/li\u003e\n\u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cb\u003eMeasurement capability\u003c\/b\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 V AC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 4 kΩ with continuity detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\/ 4000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41640292974650,"sku":"1C2090","price":207.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/323-02b-600x402.png?v=1788964539"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/collections\/F-376fc_16a_600x402_0977fa8e-a01c-42c9-a8c5-d3e15d6f99bf.png?v=1788553771","url":"https:\/\/diymetering.com\/collections\/clamp-on-meters.oembed","provider":"DIYmetering","version":"1.0","type":"link"}