{"title":"All Products","description":null,"products":[{"product_id":"200-5-cmv-current-transformer-abb","title":"200:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 200:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G01\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 200\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_200-5_7524A75G01.pdf?v=1784897804\" target=\"_blank\" rel=\"noopener\"\u003eCut Sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41555784007738,"sku":"CMV 200","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"300-5-cmv-current-transformer-abb","title":"300:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 300:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G02\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 300\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_300-5_7524A75G02.pdf?v=1784900919\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41555985432634,"sku":"CMV 300","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"400-5-cmv-current-transformer-abb","title":"400:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 400:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G03\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 400\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556247511098,"sku":"CMV 400","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"500-5-cmv-current-transformer-abb","title":"500:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 500:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G12\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 500\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_500-5_7524A75G12.pdf?v=1784903515\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556265762874,"sku":"CMV 500","price":494.73,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"600-5-cmv-current-transformer-abb","title":"600:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 600:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G04\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 600\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_600-5_7524A75G04.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556297383994,"sku":"CMV 600","price":494.73,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"800-5-cmv-current-transformer-abb","title":"800:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 800:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G05\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 800\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_800-5_7524A75G05.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556316848186,"sku":"CMV 800","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"1000-5-cmv-current-transformer-abb","title":"1000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1000:5 CMV Current Transformers\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G06\u003cbr\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 1000\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_1000-5_7524A75G06.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556329496634,"sku":"CMV 1000","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"1200-5-cmv-current-transformer-abb","title":"1200:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1200:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G07\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 1200\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_1200-5_7524A75G07.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556349616186,"sku":"CMV 1200","price":494.73,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"1500-5-cmv-current-transformer-abb","title":"1500:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1500:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G08\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 1500\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_1500-5_7524A75G08.pdf?v=1784903515\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556368031802,"sku":"CMV 1500","price":555.31,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"1600-5-cmv-current-transformer-abb","title":"1600:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 1600:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 1600\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_1600-5_7524A75G18.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556386316346,"sku":"CMV 1600","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"2000-5-cmv-current-transformer-abb","title":"2000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 2000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G09\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 2000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_2000-5_7524A75G09.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556415119418,"sku":"CMV 2000","price":575.51,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"2500-5-cmv-current-transformer-abb","title":"2500:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 2500:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 2500\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_2500-5_7524A75G21.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556455817274,"sku":"CMV 2500","price":494.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"3000-5-cmv-current-transformer-abb","title":"3000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 3000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G10\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 3000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_3000-5_7524A75G10.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556469383226,"sku":"CMV 3000","price":585.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"4000-5-cmv-current-transformer-abb","title":"4000:5 CMV Current Transformer | ABB","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ABB 4000:5 CMV Current Transformers\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7524A75G11\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e CMV 4000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_4000-5_7524A75G11.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/CMV_400-5_7524A75G03.pdf?v=1784903514\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact for pricing\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe CMV transformer is designed for pad-mounted distribution transformer metering. It is available in two external designs, tapered bottom and wide bottom, for adaptability to a variety of mounting \u003cspan\u003earrangements\u003c\/span\u003e. Both designs can be mounted directly over the LV terminals of pad mounted distribution transformers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003eThe CMV transformer has an oval shaped ring-type core and fully distributed winding assembled around a glass-filled polypropylene window liner.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFeatures:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e600 volt indoor or outdoor, 10 kV BIL, 25 through 60 hertz\u003c\/li\u003e\n\u003cli\u003ePrimary amperes: CMV 100-4000; CMV Hi-Temp 200-4000\u003c\/li\u003e\n\u003cli\u003e3.5\" x 4.5\" (88.9 mm x 114.3 mm) oval window\u003c\/li\u003e\n\u003cli\u003eDesigned for pad-mounted distribution transformer metering\u003c\/li\u003e\n\u003cli\u003eThis unit meets all applicable IEEE and NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eInsulation\u003c\/h5\u003e\n\u003cp\u003eThermoplastic rubber insulating material is permanently molded to the core and coil assembly on both designs, resulting in a compact unit with excellent mechanical, thermal, and dielectric characteristics.\u003c\/p\u003e\n\u003ch5\u003ePrimary\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV-Hi Temp both have an oval primary opening suited to fit over the secondary spade in pad-mounted transformers.\u003c\/p\u003e\n\u003ch5\u003eSecondary terminals and cover\u003c\/h5\u003e\n\u003cp\u003eThe CMV and CMV Hi-Temp transformers are supplied with large compression-type secondary terminals, a short circuit device, and a clear, rectangular snap-on cover suitable for locking with a meter seal. This clear plastic cover allows a visual check of connections and is keyed to a short circuit device to ensure proper installation. Terminals can also serve as a posttype connector by looping wire under the screw head.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":41556485963834,"sku":"CMV 4000","price":585.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/abb_cmv_360px.png?v=1784897848"},{"product_id":"200-5-dcdw-current-transformer-ritz","title":"200:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 200:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 200\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557556035642,"sku":"DCDW 200","price":197.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"300-5-dcdw-current-transformer-ritz","title":"300:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 300:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 300\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 300 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557556297786,"sku":"DCDW 300","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"400-5-dcdw-current-transformer-ritz","title":"400:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 400:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 400\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 400 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557560328250,"sku":"DCDW 400","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"600-5-dcdw-current-transformer-ritz","title":"600:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 600:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 600\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 600 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 4\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557561376826,"sku":"DCDW 600","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"800-5-dcdw-current-transformer-ritz","title":"800:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 800:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 800\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 800 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 3\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557566816314,"sku":"DCDW 800","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"1000-5-dcdw-current-transformer-ritz","title":"1000:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 1000:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 1000\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 1000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 2\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557581103162,"sku":"DCDW 1000","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"1200-5-dcdw-current-transformer-ritz","title":"1200:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 1200:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 1200\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 1200 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 2\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557581758522,"sku":"DCDW 1200","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"1500-5-dcdw-current-transformer-ritz","title":"1500:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 1500:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 1500\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 1500 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 2\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557582774330,"sku":"DCDW 1500","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"2000-5-dcdw-current-transformer-ritz","title":"2000:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 2000:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 2000\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 2000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 1.5\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557584347194,"sku":"DCDW 2000","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"3000-5-dcdw-current-transformer-ritz","title":"3000:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 3000:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 3000\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 3000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 1.33\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557603024954,"sku":"DCDW 3000","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"4000-5-dcdw-current-transformer-ritz","title":"4000:5 DCDW Current Transformer | Ritz","description":"\u003cp\u003e\u003cstrong\u003eModel Number: \u003c\/strong\u003eByram 4000:5 DCDW Indoor Padmount Type CT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number: \u003c\/strong\u003eDCDW 4000\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003ePrimary currents: \u003c\/strong\u003eUp to 4000 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eSecondary current: \u003c\/strong\u003e5 Amps\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eInner diameter: \u003c\/strong\u003e3.5\" [88mm] x 4.1\" [104.3mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eOuter diameter\u003c\/strong\u003e: 9.1\" [232mm]\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eRating Factors: \u003c\/strong\u003eUp to RF 1\u003c\/li\u003e\n\u003cli id=\"product\"\u003e\n\u003cstrong\u003eMetering class: \u003c\/strong\u003e0.3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.3% standard accuracy, No Baseplate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Description\u003c\/strong\u003e\u003cbr\u003eThe DCDW is a large window type current transformer designed for use with watt-hour meters and intended for installation around secondary bushings in pad mount transformers. Special designs are available for operating in high temperature environments up to 85° C. The transformer meets all applicable IEEE, ANSI and NEMA standards.  A wide variety of accessories and ratings allows for maximum versatility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eThe oval core is wound from high quality grain-oriented silicon steel which has been annealed. The secondary winding is accomplished with heavy enameled copper wire evenly distributed around the core. The core and coil assembly is then completely encapsulated in polyurethane resin inside a molded shell of tough glass reinforced nylon. The tapered lower half of the outer shell allows for a tight triangular fitting when the middle unit is mounted upside down.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Terminals and Cover\u003c\/strong\u003e\u003cbr\u003eSecondary terminals are tinned bronze compression type with a large 7.5 mm (.29”) diameter cross-hole. A bronze pivoting short circuit device interferes with the proper placement of the clear polycarbonate cover when the shorting device is in the shorted position. The terminal cover is designed to accept a sealing device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cbr\u003eThe transformer is designed for wall mounting and comes with 2 through holes. Also standard are removable bus bar clips for attaching the transformer to the terminal spades inside the transformer cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Reports\u003c\/strong\u003e\u003cbr\u003eTest reports according to the latest revisions of IEEE C57.13 are stored electronically at time of test and can be sent via email in customer preferred formats at time of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Accuracy Options\u003c\/strong\u003e\u003cbr\u003eFor high-accuracy and other options, consult the Byram Labs sales team\u003c\/p\u003e","brand":"Ritz","offers":[{"title":"Default Title","offer_id":41557673639994,"sku":"DCDW 4000","price":245.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/RitzDCDW.webp?v=1784918357"},{"product_id":"150-5-split-core-current-transformer-bl-2-150-ra005","title":"150:5 Split-Core Current Transformer | BL-2-150-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-150-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-2-150-RA005\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 150A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557696872506,"sku":"BL-2-150-RA005","price":37.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-2_1.png?v=1784921913"},{"product_id":"300-5-split-core-current-transformer-bl-2-300-ra005","title":"300:5 Split-Core Current Transformer | BL-2-300-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-300-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-2-300-RA005\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 300A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557698740282,"sku":"BL-2-300-RA005","price":43.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-2_1.png?v=1784921913"},{"product_id":"400-5-split-core-current-transformer-bl-2-400-ra005","title":"400:5 Split-Core Current Transformer | BL-2-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-2-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-2-400-RA005\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-2 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.0” x 1.4” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 0.5Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557700935738,"sku":"BL-2-400-RA005","price":37.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-2_1.png?v=1784921913"},{"product_id":"100-5-split-core-current-transformer-bl-4-100-ra005","title":"100:5 Split-Core Current Transformer | BL-4-100-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-100-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-4-100-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 100A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL4100.pdf?v=1784926293\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557704245306,"sku":"BL-4-100-RA005","price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl_4.png?v=1784922565"},{"product_id":"200-5-split-core-current-transformer-bl-4-200-ra005","title":"200:5 Split-Core Current Transformer | BL-4-200-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-4-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 200A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557712764986,"sku":"BL-4-200-RA005","price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl_4.png?v=1784922565"},{"product_id":"300-5-split-core-current-transformer-bl-4-300-ra005-copy","title":"300:5 Split-Core Current Transformer | BL-4-300-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-300-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-4-300-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 300A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557714534458,"sku":"BL-4-300-RA005","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl_4.png?v=1784922565"},{"product_id":"400-5-split-core-current-transformer-bl-4-400-ra005","title":"400:5 Split-Core Current Transformer | BL-4-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-4-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-4-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL4400.pdf?v=1784926220\" target=\"_blank\" rel=\"noopener\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-4 Series provides precision measurement for sub-metering,\u003cbr\u003econtrols and energy management without dismantling\u003cbr\u003ethe main line. Ergonomically designed with secured latch and\u003cbr\u003ekeying hole for locking or servicing tag.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 1.3” x 1.7” window opening (ID)\u003cbr\u003e• Secured latch \u0026amp; keying hole for locking\/service tag\u003cbr\u003e• Swing open for ease of installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• 6ft black\/white twisted pair leads - 16 or 18AWG\u003cbr\u003e• Phoenix style and other terminals (option)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 100 - 400A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5\u003cbr\u003e• Approximate weight 1.1Lbs\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557715943482,"sku":"BL-4-400-RA005","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl_4.png?v=1784922565"},{"product_id":"200-5-split-core-current-transformer-bl-5-200-ra005","title":"200:5 Split-Core Current Transformer | BL-5-200-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 200A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557717254202,"sku":"BL-5-200-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_a0188e49-2b31-4537-b397-b220152d42af.png?v=1784924138"},{"product_id":"400-5-split-core-current-transformer-bl-5-400-ra005","title":"400:5 Split-Core Current Transformer | BL-5-400-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-400-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 400A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL5400.pdf?v=1784926625\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557718466618,"sku":"BL-5-400-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_0c88db88-62cc-4e3e-b88b-5d4458d596eb.png?v=1784924116"},{"product_id":"500-5-split-core-current-transformer-bl-5-500-ra005","title":"500:5 Split-Core Current Transformer | BL-5-500-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-500-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-500-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 500A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL5500.pdf?v=1784926416\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557719253050,"sku":"BL-5-500-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_1bb3b87f-5f11-446b-a63c-359765f13dba.png?v=1784924084"},{"product_id":"600-5-split-core-current-transformer-bl-5-600-ra005","title":"600:5 Split-Core Current Transformer | BL-5-600-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 600A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL5600.pdf?v=1784926568\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557724889146,"sku":"BL-5-600-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_1bb3b87f-5f11-446b-a63c-359765f13dba.png?v=1784924084"},{"product_id":"800-5-split-core-current-transformer-bl-5-800-ra005","title":"800:5 Split-Core Current Transformer | BL-5-800-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-800-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-800-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL5800.pdf?v=1784926525\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557725872186,"sku":"BL-5-800-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_1bb3b87f-5f11-446b-a63c-359765f13dba.png?v=1784924084"},{"product_id":"1000-5-split-core-current-transformer-bl-5-1000-ra005","title":"1000:5 Split-Core Current Transformer | BL-5-1000-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-5-1000-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-5-1000-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 1000A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL51000.pdf?v=1784926469\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-5 Series provides precision measurement for sub-metering, controls\u003cbr\u003eand energy management without dismantling the main line. Ergonomically\u003cbr\u003edesigned with secured latches and keying holes, this CT handles medium to\u003cbr\u003ehigh load while retaining compact size.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 3.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 200 - 1000A\u003cbr\u003e• Frequency 50Hz - 400Hz\u003cbr\u003e• Custom Design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.5 (Varied by models)\u003cbr\u003e• Approximate weight 1.7Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557726527546,"sku":"BL-5-1000-RA005","price":202.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl-5_1bb3b87f-5f11-446b-a63c-359765f13dba.png?v=1784924084"},{"product_id":"600-5-split-core-current-transformer-bl-6-600-ra005","title":"600:5 Split-Core Current Transformer | BL-6-600-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-6-600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-6-600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 600A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-6 Series provides precision measurement for sub-metering, controls and energy management without dismantling the main line. Ergonomically designed with secured latches and keying holes, this CT has the largest ID of BL Series making suitable for high load applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 5.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 300-2000A\u003cbr\u003e• Frequency 50Hz — 400Hz\u003cbr\u003e• Custom design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.75 (Varied by models)\u003cbr\u003e• Approximate weight 2.2Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557730852922,"sku":"BL-6-600-RA005","price":242.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl6.png?v=1784924597"},{"product_id":"800-5-split-core-current-transformer-bl-6-800-ra005","title":"800:5 Split-Core Current Transformer | BL-6-800-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-6-800-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-6-800-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-6 Series provides precision measurement for sub-metering, controls and energy management without dismantling the main line. Ergonomically designed with secured latches and keying holes, this CT has the largest ID of BL Series making suitable for high load applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 5.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 300-2000A\u003cbr\u003e• Frequency 50Hz — 400Hz\u003cbr\u003e• Custom design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.75 (Varied by models)\u003cbr\u003e• Approximate weight 2.2Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557737046074,"sku":"BL-6-800-RA005","price":242.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl6.png?v=1784924597"},{"product_id":"1200-5-split-core-current-transformer-bl-6-1200-ra005","title":"1200:5 Split-Core Current Transformer | BL-6-1200-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-6-1200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-6-1200-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 1200A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-6 Series provides precision measurement for sub-metering, controls and energy management without dismantling the main line. Ergonomically designed with secured latches and keying holes, this CT has the largest ID of BL Series making suitable for high load applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 5.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 300-2000A\u003cbr\u003e• Frequency 50Hz — 400Hz\u003cbr\u003e• Custom design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.75 (Varied by models)\u003cbr\u003e• Approximate weight 2.2Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557739536442,"sku":"BL-6-1200-RA005","price":242.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl6.png?v=1784924597"},{"product_id":"1600-5-split-core-current-transformer-bl-6-1600-ra005","title":"1600:5 Split-Core Current Transformer | BL-6-1600-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-6-1600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-6-1600-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 1600A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-6 Series provides precision measurement for sub-metering, controls and energy management without dismantling the main line. Ergonomically designed with secured latches and keying holes, this CT has the largest ID of BL Series making suitable for high load applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 5.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 300-2000A\u003cbr\u003e• Frequency 50Hz — 400Hz\u003cbr\u003e• Custom design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.75 (Varied by models)\u003cbr\u003e• Approximate weight 2.2Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557742059578,"sku":"BL-6-1600-RA005","price":242.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl6.png?v=1784924597"},{"product_id":"2000-5-split-core-current-transformer-bl-6-2000-ra005","title":"2000:5 Split-Core Current Transformer | BL-6-2000-RA005","description":"\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e BL-6-2000-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Number:\u003c\/strong\u003e BL-6-2000-RA005 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Rating:\u003c\/strong\u003e 2000A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput: 5A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/BL62000.pdf?v=1784926807\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe BL-6 Series provides precision measurement for sub-metering, controls and energy management without dismantling the main line. Ergonomically designed with secured latches and keying holes, this CT has the largest ID of BL Series making suitable for high load applications.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e• 2.0” x 5.5” window opening (ID)\u003cbr\u003e• Double secured latches per side \u0026amp; keying holes\u003cbr\u003e• Built-in tabs for easy removal and installation\u003cbr\u003e• Rigid housing case with UL 94V-0 durable plastic\u003cbr\u003e• Ergonomically designed with no exposed metals\u003cbr\u003e• 8-32 screw terminals (Type A)\u003cbr\u003e• Pigtail black\/white wire leads (Type B)\u003c\/p\u003e\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e• Energy and sub-metering products\u003cbr\u003e• Electrical load monitoring\u003cbr\u003e• Network equipment\u003cbr\u003e• Instruments and sensors\u003cbr\u003e• Control systems\u003cbr\u003e• Go GREEN initiatives\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cp\u003e• Standard Input Current 300-2000A\u003cbr\u003e• Frequency 50Hz — 400Hz\u003cbr\u003e• Custom design Turns-Ratio available\u003cbr\u003e• Standard accuracy 0.75 (Varied by models)\u003cbr\u003e• Approximate weight 2.2Lbs\u003cbr\u003e• Clamping voltage on selected models\u003cbr\u003e• ANSI C57.13 and C12.20 Standards\u003c\/p\u003e","brand":"Wattcore","offers":[{"title":"Default Title","offer_id":41557749203002,"sku":"BL-6-2000-RA005","price":242.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/bl6.png?v=1784924597"},{"product_id":"commercial-electric-submeter-3-phase-4-wire-the-byram-b30-with-modbus","title":"Commercial Electric Submeter - 3 Phase 4 Wire | The Byram B30 with MODbus","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/B30-MODbus.pdf?v=1785157709\" target=\"_blank\" rel=\"noopener\"\u003eCut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-Reliable, Revenue Grade 0.2% \u003cbr\u003e-UV resistant polycarbonate enclosure \u003cbr\u003e-IP66 sealed case maintains accuracy and prolongs meter life\u003cbr\u003e-MODbus (RS485) with pulse for building automation systems. \u003cbr\u003e-Quick and easy to install\u003cbr\u003e-Measurement of 61 power parameters.\u003c\/p\u003e\n\u003cp\u003eThe “Byram” B30MOD Three Phase meter was designed to meet today's most demanding commercial and industrial requirements. The B30MOD offers 3 of the most popular automation communication protocols. Included is RS 485 MODBUS, one the most modern and user friendly interface, pulse output with an optional Ethernet.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRevenue Metering\u003c\/strong\u003e\u003cbr\u003eThe “Byram” B30MOD meter is a highly accurate revenue meter (0.2 accuracy Class).\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFlexibility and Future Growth\u003c\/strong\u003e\u003cbr\u003eThe B30MOD series has been developed as a walk up and read meter. Meters are programmed for kWh readings (purchase of energy) but have an option for instrumentation metering*. Each B30MOD is furnished with a pulse output compatible with most Building Automation Systems (BAS). \u003cbr\u003eEach B30MOD meter is capable of being upgraded with software to display or transmit optional electrical parameters.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTechnical Specifications\u003cbr\u003e\u003c\/strong\u003e-Operating Temperature: -20 to +70C\u003cbr\u003e-Storage Temperature: -30 to +80C\u003cbr\u003e-Relative Humidity: 0... 90% non condensing\u003cbr\u003e-Warm Up Time: Minimum 3 minutes\u003cbr\u003e-Shock: 15g in 3 planes\u003cbr\u003e-Vibration: 10... 55... 10 Hz, 0.15mm amplitude\u003cbr\u003e-Relay Contact: (1NO+1NC)\u003cbr\u003e-Switching Voltage and Current for Relay: 240 VAC, 5A\u003c\/p\u003e\n\u003cp\u003eDefault Pulse Rate Divisor:\u003cbr\u003e-1 per Wh (up to 3600W)\u003cbr\u003e-1 per kWh (up to 3600kWh)\u003cbr\u003e-1 per MWh (above 3600kW)\u003c\/p\u003e\n\u003cp\u003eOther Pulse Rate Divisors:\u003cbr\u003e-10 | 1 per 10 Wh (up to 3600W) | 1 per 10 kWh (up to 3600kWh) | 1 per 10 MWh (up to 3600kW)\u003cbr\u003e-100 | 1 per 100 Wh (up to 3600W) | 1 per 100 kWh (up to 3600kWh) | 1 per 10 MWh (up to 3600kW)\u003cbr\u003e-1000 | 1 per 1000 Wh (up to 3600W) | 1 per 100 kWh (up to 3600kWh) | 1 per 10 MWh (up to 3600kW)\u003c\/p\u003e","brand":"Byram Labs","offers":[{"title":"Default Title","offer_id":41560772739130,"sku":null,"price":1800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/7383\/7626\/files\/B30.png?v=1785156881"}],"url":"https:\/\/diymetering.com\/collections\/all-products.oembed","provider":"DIYmetering","version":"1.0","type":"link"}